9. Seal all exposed perimeter joints between structure and door frame perimeters with a
skinning, non-hardening type of sealant. Refer to the approved shop drawings for joint
design. (See Figs. P and Q)
10. Seal all frame to frame and frame to accessory (subframe, panning, mullions) joints with
compatible silicone sealant. Refer to the approved shop drawings for joint design. (See
Figs. P and Q)
Note: All perimeter sealants must be continuous with one another and tooled with no voids.
Note: Ensure that the perimeter shims do not interfere with the exterior and interior
perimeter sealant joints that are to be in accordance with the sealant manufacturer’s
recommendations.