EFCO CORPORATION 6/2012 PART NO. Y557
25
Series 5500 Advanced & Alternate Installation Instructions
Section V: Vertical Splice Joints
SPLICE SLEEVE
STOP SCREW
COVER
SPLICE
MULLION LENGTH
COVER LENGTHCOVER LENGTH
MULLION LENGTH
GLAZING ADAPTER AND REAR
MULLION SECTION LENGTH
5 1/2"
GLAZING ADAPTER AND REAR
MULLION SECTION LENGTH
5/8"(MIN.)
2"
3 " NOTCH
3 " NOTCH
MULLION
SPLICE
1/2"
1/2"
1/2"
NOTE: All anchors must be fixed before glazing begins.
SIDE VIEW – MULLION SPLICE